Skip to content
Fencer Intel
medium 4.9

CVE-2025-62288 json

Vulnerability in the Oracle Health Sciences Data Management Workbench product of Oracle Health Sciences Applications (component: Logger).

published last yr. modified last mo. also EUVD-2025-35224

cvss
4.9
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 23%
public exploits
0
none known

Summary

Vulnerability in the Oracle Health Sciences Data Management Workbench product of Oracle Health Sciences Applications (component: Logger). Supported versions that are affected are 3.4.0.1.3 and 3.4.1.0.10. Easily exploitable vulnerability allows high privileged attacker with network access via HTTP to compromise Oracle Health Sciences Data Management Workbench. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Health Sciences Data Management Workbench accessible data. CVSS 3.1 Base Score 4.9 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).

Is CVE-2025-62288 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
last yr.

Exploit prediction

0.30% chance of exploitation in the next 30 days, higher than 23% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 4.9 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N

Affected products

  • Oracle Corporation Oracle Health Sciences Data Management Workbench

Classification

Weakness
  • CWE-267 Privilege Defined With Unsafe Actions

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.