Skip to content
Fencer Intel
high 7.4

CVE-2025-68136 json

EVerest's inadequate session handling can lead to memory-related errors or exhaustion of the operating system’s file descriptors, resulting in a denial of service

published 9mo ago modified 4mo ago also EUVD-2025-206318

cvss
7.4
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 23%
public exploits
0
none known

Summary

EVerest is an EV charging software stack. Prior to version 2025.10.0, once the module receives a SDP request, it creates a whole new set of objects like `Session`, `IConnection` which open new TCP socket for the ISO15118-20 communications and registers callbacks for the created file descriptor, without closing and destroying the previous ones. Previous `Session` is not saved and the usage of an `unique_ptr` is lost, destroying connection data. Latter, if the used socket and therefore file descriptor is not the last one, it will lead to a null pointer dereference. Version 2025.10.0 fixes the issue.

Patch / fix

  • linuxfoundation everest 2025.10.0

Is CVE-2025-68136 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
partial
Assessed
9mo ago

Exploit prediction

0.30% chance of exploitation in the next 30 days, higher than 23% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • github.com https://github.com/EVerest/everest-core/security/advisories/GHSA-4h8h-x5cp-g22r referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 3.1 7.4 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

Affected products

  • EVerest everest-core

Classification

Weakness
  • CWE-770 Allocation of Resources Without Limits or Throttling

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.