Skip to content
Fencer Intel
critical 9.8

CVE-2025-71316 json

SQLite sqldiff remote code execution via argument injection

published 5mo ago modified 26d ago also EUVD-2025-210067

cvss
9.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 45%
public exploits
0
none known

Summary

SQLite 'sqldiff.exe' does not securely handle the way the Microsoft Windows C runtime converts Unicode characters to ANSI codepages. An attacker could use the '-L' option to load an arbitrary DLL with a crafted command line argument string that results in command line file arguments being misinterpreted as command line options. Fixed on or around 2025-12-26.

Patch / fix

  • SQLite sqldiff 2025-12-26
  • Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) V6.0

Is CVE-2025-71316 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-26-295-15 updated cvss 9.8

Siemens RUGGEDCOM CROSSBOW Station Access Controller

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

cisa vex VA-26-155-01 updated cvss 7.8

SQLite sqldiff remote code execution via argument injection

  • SQLite sqldiff <2025-12-26
    affected: vendor fix sqlite.org
  • SQLite sqldiff 2025-12-26
    fixed: vendor fix sqlite.org

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
total
Assessed
5mo ago

Exploit prediction

0.54% chance of exploitation in the next 30 days, higher than 45% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • i.blackhat.com https://i.blackhat.com/EU-24/Presentations/EU-24-Tsai-V2-WorstFit-Unveiling-Hidden-Transformers-in-Windows-ANSI.pdf referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CNA 4.0 9.2 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 9.2 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • SQLite sqldiff
  • Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC)

Classification

Weakness
  • CWE-176 Improper Handling of Unicode Encoding

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.