Skip to content
Fencer Intel
medium 6.3

CVE-2025-7932 json

D-Link DIR‑817L ssdpcgi lxmldbc_system command injection

published last yr. modified 4mo ago also EUVD-2025-22123

cvss
6.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
5.9%
EPSS 5.9% chance of exploitation in 30 days, percentile 93%
public exploits
0
none known

Summary

A vulnerability classified as critical has been found in D-Link DIR‑817L up to 1.04B01. This affects the function lxmldbc_system of the file ssdpcgi. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Patch / fix

  • dlink dir-817l_firmware 1.04b01

Is CVE-2025-7932 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
partial
Assessed
last yr.

Exploit prediction

5.93% chance of exploitation in the next 30 days, higher than 93% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • github.com https://github.com/Patr1ck-S/Patr1ck-S.github.io/blob/main/D-Link%20DIR%E2%80%91817L%20has%20a%20remote%20arbitrary%20command%20execution%20vulnerability%20in%20ssdpcgi(1).md referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 5.3 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
CNA 3.1 6.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
CNA 3.0 6.3 CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
CNA 2.0 6.5 AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
CNA 4.0 2.1 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 6.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
NVD 3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CNA 2.0 6.5 AV:N/AC:L/Au:S/C:P/I:P/A:P

Affected products

  • D-Link DIR‑817L

Classification

Weakness
  • CWE-77 Improper Neutralization of Special Elements used in a Command
  • CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.