CVE-2025-8907 json
H3C M2 NAS Webserver Configuration unnecessary privileges
published last yr. modified 4mo ago also EUVD-2025-24564
- cvss
- 7.0
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 8%
- public exploits
- 0
- none known
Summary
A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer.
Is CVE-2025-8907 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- last yr.
Exploit prediction
0.19% chance of exploitation in the next 30 days, higher than 8% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- notion.so https://www.notion.so/23f54a1113e7804bae88e76f9fb0cf5b referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 7.3 | CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P |
| CNA | 3.1 | 7.0 | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| CNA | 3.0 | 7.0 | CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| CNA | 2.0 | 6.0 | AV:L/AC:H/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR |
| CNA | 4.0 | 6.4 | CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 7.0 | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 2.0 | 6.0 | AV:L/AC:H/Au:S/C:C/I:C/A:C |
Affected products
- H3C M2 NAS
Classification
- Weakness
-
- CWE-250 Execution with Unnecessary Privileges
References
-
notion.so
/23f54a1113e7804bae88e76f9fb0cf5b
exploit
-
vuldb.com
/?id.319861
vdb-entry
-
vuldb.com
/?ctiid.319861
signature, permissions-required
-
vuldb.com
/?submit.624554
third-party-advisory
Sources
- CVE List CVE-2025-8907
- NVD CVE-2025-8907
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.