CVE-2025-9356 json
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 inboundFilterAdd stack-based overflow
published last yr. modified 4mo ago also EUVD-2025-28837
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.0%
- EPSS 1.0% chance of exploitation in 30 days, percentile 63%
- public exploits
- 0
- none known
Summary
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function inboundFilterAdd of the file /goform/inboundFilterAdd. Executing manipulation of the argument ruleName can lead to stack-based buffer overflow. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
Is CVE-2025-9356 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- total
- Assessed
- last yr.
Exploit prediction
1.02% chance of exploitation in the next 30 days, higher than 63% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- github.com https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_24/24.md referenced PoC, tagged "exploit" by a source, unverified
- github.com https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_24/24.md#poc referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| CNA | 3.0 | 8.8 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR |
| CNA | 4.0 | 7.4 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Affected products
- Linksys RE6250
- Linksys RE6300
- Linksys RE6350
- Linksys RE6500
- Linksys RE7000
- Linksys RE9000
Classification
References
-
github.com
/wudipjq/my_vuln/blob/main/Linksys/vuln_24/24.md
related, exploit, third-party-advisory
-
github.com
/wudipjq/my_vuln/blob/main/Linksys/vuln_24/24.md#poc
exploit, third-party-advisory
-
vuldb.com
/?id.321059
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.321059
signature, permissions-required
-
vuldb.com
/?submit.631528
third-party-advisory, vdb-entry
-
linksys.com
/
product
Sources
- CVE List CVE-2025-9356
- NVD CVE-2025-9356
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.