Skip to content
Fencer Intel
high 7.3

CVE-2025-9759 json

Campcodes/SourceCodester Courier Management System ajax.php signup sql injection

published last yr. modified 22d ago also EUVD-2025-26325

cvss
7.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 37%
public exploits
0
none known

Summary

A security flaw has been discovered in Campcodes/SourceCodester Courier Management System 1.0. Affected by this issue is the function Signup of the file /ajax.php. Performing manipulation of the argument lastname results in sql injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be exploited.

Is CVE-2025-9759 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
Proof of concept is public
Automatable
yes
Technical impact
partial
Assessed
last yr.

Exploit prediction

0.43% chance of exploitation in the next 30 days, higher than 37% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • github.com https://github.com/lrjbsyh/CVE_Hunter/issues/9#issue-3348584620 referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
CNA 3.1 7.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
CNA 3.0 7.3 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
CNA 2.0 7.5 AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
CNA 4.0 5.5 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 7.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
NVD 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CNA 2.0 7.5 AV:N/AC:L/Au:N/C:P/I:P/A:P

Affected products

  • Campcodes Courier Management System
  • SourceCodester Courier Management System

Classification

Weakness
  • CWE-89 Improper Neutralization of Special Elements used in an SQL Command
  • CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.