Summary

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate user input in multipart handling. This could allow an unauthenticated remote attacker to cause a denial of service.

Patch / fix

  • Siemens APOGEE PXC Compact (BACnet) V3.5.7
  • Siemens APOGEE PXC Compact (P2 Ethernet) V2.8.21
  • Siemens APOGEE PXC Modular (BACnet) V3.5.7
  • Siemens APOGEE PXC Modular (P2 Ethernet) V2.8.21
  • Siemens TALON TC Compact (BACnet) V3.5.7
  • Siemens TALON TC Modular (BACnet) V3.5.7

Is CVE-2026-102075 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-26-295-08 updated cvss 7.5

Siemens APOGEE, TALON and Desigo PXC/PXM Products

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
27d ago

Exploit prediction

0.42% chance of exploitation in the next 30 days, higher than 36% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Siemens APOGEE MBC (PPC) (BACnet)
  • Siemens APOGEE MBC (PPC) (P2 Ethernet)
  • Siemens APOGEE MEC (PPC) (BACnet)
  • Siemens APOGEE MEC (PPC) (P2 Ethernet)
  • Siemens APOGEE PXC Compact (BACnet)
  • Siemens APOGEE PXC Compact (P2 Ethernet)
  • Siemens APOGEE PXC Modular (BACnet)
  • Siemens APOGEE PXC Modular (P2 Ethernet)
  • Siemens TALON TC Compact (BACnet)
  • Siemens TALON TC Modular (BACnet)

Classification

Weakness
  • CWE-121 Stack-based Buffer Overflow

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.