Skip to content
Fencer Intel
critical 9.8

CVE-2026-116779 kev in the critical feed json

FreeSWITCH: Inbound SIP MESSAGE can select the api chat proto and run FreeSWITCH API commands

published 4d ago modified 3h ago also EUVD-2026-117752

cvss
9.8
version 3.1, CNA
cisa kev
Exploited
added 2026-11-09
epss
1.3%
EPSS 1.3% chance of exploitation in 30 days, percentile 70%
public exploits
0
none known

Summary

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.3, sofia_presence_handle_sip_i_message() split the To user of an inbound SIP MESSAGE on a plus sign and treated the left side as a chat protocol selector. Selecting the api chat proto reached switch_api_execute(), allowing a peer whose MESSAGE was accepted to run FreeSWITCH API commands, including operating-system command sinks, with the daemon's privileges. Inbound chat is enabled on the stock internal and external profiles, and any authenticated profile account is sufficient; stock directory users without password material can also remove that barrier in affected configurations. The flaw permits configuration and credential disclosure, arbitrary call control, and command execution, and exploitation has been observed in the wild. This issue is fixed in version 1.11.3.

Patch / fix

cisa required action Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

Is CVE-2026-116779 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Timeline

  1. Published
  2. Added to CISA KEV
  3. CISA SSVC: exploitation active
  4. CISA patch deadline

Known exploited

Added
yesterday
Patch by
2026-11-12 (tomorrow)
Ransomware
Not known
Required action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Vendor, product
SignalWire, FreeSwitch
CISA name
SignalWire FreeSwitch Code Injection Vulnerability

CISA SSVC

Exploitation
Active, exploited in the wild
Automatable
yes
Technical impact
total
Assessed
7h ago

Exploit prediction

1.30% chance of exploitation in the next 30 days, higher than 70% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

  • signalwire freeswitch

Classification

Weakness
  • CWE-77 Improper Neutralization of Special Elements used in a Command
  • CWE-78 Improper Neutralization of Special Elements used in an OS Command
  • CWE-749 Exposed Dangerous Method or Function

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.