CVE-2026-124464 json
OpenEMR before 8.4.0 FHIR Patient Compartment Bypass via QuestionnaireResponse
published last mo. modified yesterday also EUVD-2026-119521 , GHSA-fmmr-p679-97fq
Unreviewed: the maintainers' own advisory
Published by the maintainers on their GitHub repository openemr/openemr. GitHub has not reviewed it into the GitHub Advisory Database, so the affected packages and versions are the maintainers' word. Read the full advisory on GitHub.
- cvss
- 6.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 19%
- public exploits
- 0
- none known
Summary
OpenEMR before 8.4.0 contains an authorization bypass vulnerability that allows patient-scoped SMART tokens to read other patients' questionnaire responses because FhirQuestionnaireResponseService does not implement IPatientCompartmentResourceService. Attackers holding a patient/QuestionnaireResponse.rs token can request responses by uuid or list the unfiltered bundle to obtain cross-patient clinical assessment answers.
Patch / fix
- openemr openemr 8.4.0
Is CVE-2026-124464 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- yesterday
Exploit prediction
0.27% chance of exploitation in the next 30 days, higher than 19% of all scored CVEs (FIRST EPSS, 2026-11-11).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 7.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N |
| CNA | 4.0 | 7.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- openemr openemr
Classification
- Weakness
-
- CWE-639 Authorization Bypass Through User-Controlled Key
References
-
github.com
/openemr/openemr/security/advisories/GHSA-fmmr-p679-97fq
vendor-advisory, advisory
-
vulncheck.com
/advisories/openemr-before-8.4.0-fhir-patient-compartment-bypass-via-questionnaireresponse
third-party-advisory
Sources
- CVE List CVE-2026-124464
- NVD CVE-2026-124464
- Maintainer advisory GHSA-fmmr-p679-97fq
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.
The maintainers of openemr/openemr published their own advisory on GitHub. Reviewed sources take precedence over it.