Skip to content
Fencer Intel
high 8.7

CVE-2026-124646 json

Insecure Direct Object Reference (IDOR) Vulnerability in e-Sushrut HMIS

published yesterday modified yesterday also EUVD-2026-126987

cvss
8.7
version 4.0, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 43%
public exploits
0
none known

Summary

This vulnerability exists in e-Sushrut HMIS due to insufficient server side object level authorization validation in the API endpoint. An unauthenticated remote attacker could exploit this vulnerability by modifying the parameter value in the API request.

Successful exploitation of this vulnerability could allow the attacker to enumerate and gain unauthorized access to sensitive information of patients on the targeted healthcare organization.

Is CVE-2026-124646 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
yesterday

Exploit prediction

0.50% chance of exploitation in the next 30 days, higher than 43% of all scored CVEs (FIRST EPSS, 2026-11-18).

CVSS scores

assigned by version score vector
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • CDAC-Noida e-Sushrut, Hospital Management Information System (HMIS)

Classification

Weakness
  • CWE-639 Authorization Bypass Through User-Controlled Key

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.