CVE-2026-129450 json
DrayTek Vigor2960 mainfunction.cgi sub_1E084 path traversal
published 3d ago modified yesterday also EUVD-2026-126014
- cvss
- 9.9
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 45%
- public exploits
- 0
- none known
Summary
A vulnerability was detected in DrayTek Vigor2960 1.5.1.6. Affected by this issue is the function sub_1E084 of the file /cgi-bin/mainfunction.cgi?action=doWebBackup. The manipulation of the argument option results in path traversal. It is possible to launch the attack remotely. The exploit is now public and may be used. Upgrading to version 1.5.1.7 can resolve this issue. You should upgrade the affected component. The vendor recommends: "1.5.1.6 isn't the latest version of 2960, the latest version fixes many security issues. And we have another one in our release plan which should solve the issues reported."
Patch / fix
- DrayTek Vigor2960 1.5.1.7
Is CVE-2026-129450 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- total
- Assessed
- yesterday
Exploit prediction
0.53% chance of exploitation in the next 30 days, higher than 45% of all scored CVEs (FIRST EPSS, 2026-11-17).
Exploits and checks
- github.com https://github.com/yikesoftware/DrayTek_Vigor2960_Security_Analysis/tree/main/cases/DRV2960-0016-authenticated-dowebbackup-path-traversal-clobber referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 9.4 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P |
| CNA | 3.1 | 9.9 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C |
| CNA | 3.0 | 9.9 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:OF/RC:C |
| CNA | 4.0 | 8.6 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 9.9 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Affected products
- DrayTek Vigor2960
Classification
- Weakness
-
- CWE-22 Improper Limitation of a Pathname to a Restricted Directory
References
-
fw.draytek.com.tw
/Vigor2960/Firmware/v1.5.1.7/Vigor2960_v1.5.1.7.zip
patch
-
github.com
/yikesoftware/DrayTek_Vigor2960_Security_Analysis/tree/main/cases/DRV2960-0016-authenticated-dowebbackup-path-
exploit
-
vuldb.com
/vuln/437461
vdb-entry, technical-description
-
vuldb.com
/vuln/437461/cti
signature, permissions-required
-
vuldb.com
/cve/CVE-2026-129450
third-party-advisory
-
vuldb.com
/submit/1044958
third-party-advisory
Sources
- CVE List CVE-2026-129450
- NVD CVE-2026-129450
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.