CVE-2026-129451 json
DrayTek Vigor2960 mainfunction.cgi app_guest_export path traversal
published 3d ago modified 2d ago also EUVD-2026-126017
- cvss
- 9.9
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 45%
- public exploits
- 0
- none known
Summary
A flaw has been found in DrayTek Vigor2960 up to 1.5.1.6. This affects the function app_guest_export of the file /cgi-bin/mainfunction.cgi. This manipulation of the argument filename causes path traversal. The attack can be initiated remotely. The exploit has been published and may be used. Upgrading to version 1.5.1.7 is able to mitigate this issue. The affected component should be upgraded. The vendor recommends: "1.5.1.6 isn't the latest version of 2960, the latest version fixes many security issues. And we have another one in our release plan which should solve the issues reported."
Patch / fix
- DrayTek Vigor2960 1.5.1.7
Is CVE-2026-129451 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerExploit prediction
0.53% chance of exploitation in the next 30 days, higher than 45% of all scored CVEs (FIRST EPSS, 2026-11-17).
Exploits and checks
- github.com https://github.com/yikesoftware/DrayTek_Vigor2960_Security_Analysis/tree/main/cases/DRV2960-0017-authenticated-app-guest-export-path-traversal-write-delete referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 9.4 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P |
| CNA | 3.1 | 9.9 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C |
| CNA | 3.0 | 9.9 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:OF/RC:C |
| CNA | 4.0 | 8.6 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 9.9 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Affected products
- DrayTek Vigor2960
Classification
- Weakness
-
- CWE-22 Improper Limitation of a Pathname to a Restricted Directory
References
-
fw.draytek.com.tw
/Vigor2960/Firmware/v1.5.1.7/Vigor2960_v1.5.1.7.zip
patch
-
github.com
/yikesoftware/DrayTek_Vigor2960_Security_Analysis/tree/main/cases/DRV2960-0017-authenticated-app-guest-export-
exploit
-
vuldb.com
/vuln/437462
vdb-entry, technical-description
-
vuldb.com
/vuln/437462/cti
signature, permissions-required
-
vuldb.com
/cve/CVE-2026-129451
third-party-advisory
-
vuldb.com
/submit/1044961
third-party-advisory
Sources
- CVE List CVE-2026-129451
- NVD CVE-2026-129451
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.