Skip to content
Fencer Intel
critical 9.1

CVE-2026-129452 json

DrayTek Vigor2960 mainfunction.cgi set_table command injection

published 2d ago modified 2d ago also EUVD-2026-126018

cvss
9.1
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
2.2%
EPSS 2.2% chance of exploitation in 30 days, percentile 82%
public exploits
0
none known

Summary

A vulnerability has been found in DrayTek Vigor2960 1.5.1.6. This vulnerability affects the function set_table of the file /cgi-bin/mainfunction.cgi. Such manipulation of the argument jsondata leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.5.1.7 is able to resolve this issue. It is suggested to upgrade the affected component. The vendor recommends: "1.5.1.6 isn't the latest version of 2960, the latest version fixes many security issues. And we have another one in our release plan which should solve the issues reported."

Patch / fix

  • DrayTek Vigor2960 1.5.1.7

Is CVE-2026-129452 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Exploit prediction

2.15% chance of exploitation in the next 30 days, higher than 82% of all scored CVEs (FIRST EPSS, 2026-11-17).

Exploits and checks

  • github.com https://github.com/yikesoftware/DrayTek_Vigor2960_Security_Analysis/tree/main/cases/DRV2960-0019-authenticated-set-table-config-field-command-injection referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 9.4 CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P
CNA 3.1 9.1 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
CNA 3.0 9.1 CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
CNA 2.0 8.3 AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:OF/RC:C
CNA 4.0 8.5 CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD 3.1 9.1 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
CNA 2.0 8.3 AV:N/AC:L/Au:M/C:C/I:C/A:C

Affected products

  • DrayTek Vigor2960

Classification

Weakness
  • CWE-77 Improper Neutralization of Special Elements used in a Command
  • CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.