CVE-2026-20344 json
Cisco Secure Firewall Management Center Software SQL Injection Vulnerability
published last mo. modified last mo. also EUVD-2026-81129
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 42%
- public exploits
- 0
- none known
Summary
A vulnerability in the web-based management interface of Cisco Secure FMC Software could allow an authenticated, remote attacker to perform a SQL injection attack against an affected device. To exploit this vulnerability, the attacker must have a valid account on the device with the role of Security Approver, Access Admin, or Network Admin.
This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface of an affected device. A successful exploit could allow the attacker to obtain any data from the database, obtain the session credentials of an authenticated Administrator, and take actions with administrative privileges on the affected device.
Is CVE-2026-20344 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- last mo.
Exploit prediction
0.49% chance of exploitation in the next 30 days, higher than 42% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Cisco Cisco Secure Firewall Management Center (FMC)
Classification
- Weakness
-
- CWE-89 Improper Neutralization of Special Elements used in an SQL Command
References
Sources
- CVE List CVE-2026-20344
- NVD CVE-2026-20344
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.