Skip to content
Fencer Intel
high 7.6

CVE-2026-23775 json

Dell PowerProtect Data Domain appliances with Data Domain Operating System (DD OS) of Feature Release versions 8.0 through 8.5, LTS2025 rel…

published 6mo ago modified 14d ago also EUVD-2026-23392

cvss
7.6
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 25%
public exploits
0
none known

Summary

Dell PowerProtect Data Domain appliances with Data Domain Operating System (DD OS) of Feature Release versions 8.0 through 8.5, LTS2025 release version 8.3.1.0 through 8.3.1.10 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to credential exposures. Authentication attempts as the compromised user would need to be authorized by a high privileged DD user. This vulnerability only affects systems with retention lock enabled.

Patch / fix

  • Dell PowerProtect Data Domain appliances 8.3.1.20 or later, 8.6.0.0 or later

Is CVE-2026-23775 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
6mo ago

Exploit prediction

0.33% chance of exploitation in the next 30 days, higher than 25% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 7.6 CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:H/A:H
NVD 3.1 5.7 CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N

Affected products

  • Dell PowerProtect Data Domain appliances

Classification

Weakness
  • CWE-532 Insertion of Sensitive Information into Log File

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.