FOSSBilling has improper SQL neutralization in `Massmailer` recipient filters

published 4mo ago modified 4mo ago also EUVD-2026-41945

cvss
6.9
version 4.0, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 30%
public exploits
0
none known

Summary

FOSSBilling is a free, open-source billing and client management system. Versions 0.6.0 through 0.7.2 have a SQL injection vulnerability in the `Massmailer` module filter functionality. An authenticated administrator can supply crafted filter values when updating a mass email message, causing untrusted input to be interpolated directly into SQL in the recipient selection query. Version 0.8.0 patches the issue. Some workarounds are available. Restrict administrator access to trusted users only, disable the `Massmailer` module if it is not required, audit existing records in the `mod_massmailer` table for suspicious filter values, and/or review administrator activity related to `Massmailer` message updates.

Patch / fix

  • fossbilling fossbilling 0.8.0

Is CVE-2026-33734 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
partial
Assessed
4mo ago

Exploit prediction

0.37% chance of exploitation in the next 30 days, higher than 30% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • github.com https://github.com/FOSSBilling/FOSSBilling/security/advisories/GHSA-jf7m-j359-2899 referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • FOSSBilling FOSSBilling

Classification

Weakness
  • CWE-89 Improper Neutralization of Special Elements used in an SQL Command