Junos OS and Junos OS Evolved: In an EVPN-MPLS scenario churn of ESI routes causes a memory leak in l2ald
published 7mo ago modified 14d ago also EUVD-2026-21090
- cvss
- 6.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 7%
- public exploits
- 0
- none known
Summary
A Missing Release of Memory after Effective Lifetime vulnerability in the Layer 2 Address Learning Daemon (l2ald) of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent, unauthenticated attacker to cause a memory leak ultimately leading to a Denial of Service (DoS).
In an EVPN-MPLS scenario, routes learned from remote multi-homed Provider Edge (PE) devices are programmed as ESI routes. Due to a logic issue in the l2ald memory management, memory allocated for these routes is not released when there is churn for these routes. As a result, memory leaks in the l2ald process which will ultimately lead to a crash and restart of l2ald.
Use the following command to monitor the memory consumption by l2ald:
user@device> show system process extensive | match "PID|l2ald"
This issue affects:
Junos OS:
* all versions before 22.4R3-S5, * 23.2 versions before 23.2R2-S3, * 23.4 versions before 23.4R2-S4, * 24.2 versions before 24.2R2;
Junos OS Evolved:
* all versions before 22.4R3-S5-EVO, * 23.2 versions before 23.2R2-S3-EVO, * 23.4 versions before 23.4R2-S4-EVO, * 24.2 versions before 24.2R2-EVO.
Patch / fix
- Juniper Networks Junos OS 22.4R3-S5, 23.2R2-S3, 23.4R2-S4, 24.2R2
- Juniper Networks Junos OS Evolved 22.4R3-S5-EVO, 23.2R2-S3-EVO, 23.4R2-S4-EVO, 24.2R2-EVO
Is CVE-2026-33780 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 6mo ago
Exploit prediction
0.18% chance of exploitation in the next 30 days, higher than 7% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| CNA | 4.0 | 7.1 | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/RE:M |
| CNA | 4.0 | 7.1 | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:M/U:X |
Affected products
- Juniper Networks Junos OS
- Juniper Networks Junos OS Evolved
Classification
- Weakness
-
- CWE-401 Missing Release of Memory after Effective Lifetime
References
-
kb.juniper.net
/JSA107819
vendor-advisory