Skip to content
Fencer Intel
high 8.8

CVE-2026-4558 json

Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection

published 7mo ago modified 4mo ago also EUVD-2026-14333

cvss
8.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
5.1%
EPSS 5.1% chance of exploitation in 30 days, percentile 92%
public exploits
0
none known

Summary

A flaw has been found in Linksys MR9600 2.0.6.206937. Affected is the function smartConnectConfigure of the file SmartConnect.lua. Executing a manipulation of the argument configApSsid/configApPassphrase/srpLogin/srpPassword can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Is CVE-2026-4558 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
total
Assessed
7mo ago

Exploit prediction

5.09% chance of exploitation in the next 30 days, higher than 92% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • github.com https://github.com/utmost3/cve/issues/1 referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
CNA 3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
CNA 3.0 8.8 CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
CNA 2.0 9.0 AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
CNA 4.0 7.4 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CNA 2.0 9.0 AV:N/AC:L/Au:S/C:C/I:C/A:C

Affected products

  • Linksys MR9600

Classification

Weakness
  • CWE-78 Improper Neutralization of Special Elements used in an OS Command
  • CWE-77 Improper Neutralization of Special Elements used in a Command

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.