CVE-2026-48975 json
HomeBox: Cross-Tenant IDOR in MaintenanceEntry Update and Delete Allows Tampering and Destruction of Any User's Maintenance History in Homebox
published 4mo ago modified last mo. also EUVD-2026-84034 , GHSA-7mr6-2wxw-27j9
Unreviewed: the maintainers' own advisory
Published by the maintainers on their GitHub repository sysadminsmedia/homebox. GitHub has not reviewed it into the GitHub Advisory Database, so the affected packages and versions are the maintainers' word. Read the full advisory on GitHub.
- cvss
- 8.1
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 42%
- public exploits
- 0
- none known
Summary
HomeBox is a home inventory and organization system. Prior to 0.26.0, MaintenanceEntryRepository.Update and MaintenanceEntryRepository.Delete in backend/internal/data/repo/repo_maintenance_entry.go use UpdateOneID(id) and DeleteOneID(id) without verifying that the maintenance entry belongs to the authenticated user's active group. An authenticated low-privileged user who knows or enumerates another tenant's maintenance-entry UUID can overwrite that record or permanently delete it. This issue is fixed in version 0.26.0.
Patch / fix
- sysadminsmedia homebox 0.26.0
Is CVE-2026-48975 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- last mo.
Exploit prediction
0.49% chance of exploitation in the next 30 days, higher than 42% of all scored CVEs (FIRST EPSS, 2026-11-11).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.1 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H |
Affected products
- sysadminsmedia homebox
Classification
- Weakness
-
- CWE-639 Authorization Bypass Through User-Controlled Key
References
Sources
- CVE List CVE-2026-48975
- NVD CVE-2026-48975
- Maintainer advisory GHSA-7mr6-2wxw-27j9
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.
The maintainers of sysadminsmedia/homebox published their own advisory on GitHub. Reviewed sources take precedence over it.
CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.