HomeBox: Cross-Tenant IDOR in MaintenanceEntry Update and Delete Allows Tampering and Destruction of Any User's Maintenance History in Homebox

published 4mo ago modified last mo. also EUVD-2026-84034 , GHSA-7mr6-2wxw-27j9

Unreviewed: the maintainers' own advisory

Published by the maintainers on their GitHub repository sysadminsmedia/homebox. GitHub has not reviewed it into the GitHub Advisory Database, so the affected packages and versions are the maintainers' word. Read the full advisory on GitHub.

cvss
8.1
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 42%
public exploits
0
none known

Summary

HomeBox is a home inventory and organization system. Prior to 0.26.0, MaintenanceEntryRepository.Update and MaintenanceEntryRepository.Delete in backend/internal/data/repo/repo_maintenance_entry.go use UpdateOneID(id) and DeleteOneID(id) without verifying that the maintenance entry belongs to the authenticated user's active group. An authenticated low-privileged user who knows or enumerates another tenant's maintenance-entry UUID can overwrite that record or permanently delete it. This issue is fixed in version 0.26.0.

Patch / fix

Is CVE-2026-48975 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
last mo.

Exploit prediction

0.49% chance of exploitation in the next 30 days, higher than 42% of all scored CVEs (FIRST EPSS, 2026-11-11).

CVSS scores

assigned by version score vector
CNA 3.1 8.1 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H

Affected products

  • sysadminsmedia homebox

Classification

Weakness
  • CWE-639 Authorization Bypass Through User-Controlled Key