Skip to content
Fencer Intel
high 7.5

CVE-2026-56669 json

Elysia: Inefficient Algorithmic Complexity and Interpretation Conflict

published 4mo ago modified 17d ago also EUVD-2026-42394 , GHSA-9643-4qgh-g8mx

cvss
7.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.6%
EPSS 0.6% chance of exploitation in 30 days, percentile 50%
public exploits
0
none known

Summary

Elysia is a Typescript framework for request validation, type inference, OpenAPI documentation, and client-server communication. Prior to 1.4.29, Elysia uses getAll in form data normalization for multipart/form-data endpoints, causing the amount of work to grow quadratically with the number of unique key-value pairs and allowing CPU exhaustion. This issue is fixed in version 1.4.29.

Patch / fix

  • npm elysia 1.4.29
  • elysiajs elysia 1.4.29

Is CVE-2026-56669 in your dependencies? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
4mo ago

Exploit prediction

0.63% chance of exploitation in the next 30 days, higher than 50% of all scored CVEs (FIRST EPSS, 2026-11-11).

CVSS scores

assigned by version score vector
CNA 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
GitHub 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Affected packages

ecosystem package affected fixed in
npm elysia
<1.4.29
1.4.29

Affected products

  • elysiajs elysia

Classification

Weakness
  • CWE-407 Inefficient Algorithmic Complexity
  • CWE-436 Interpretation Conflict

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.

The maintainers of elysiajs/elysia published their own advisory on GitHub. Reviewed sources take precedence over it.

CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.