Skip to content
Fencer Intel
high 8.8

CVE-2026-71966 json

CyberPanel 2.4.3 Authenticated Command Injection via starRemoteTransfer

published 3mo ago modified 18d ago also EUVD-2026-55736

cvss
8.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
3.3%
EPSS 3.3% chance of exploitation in 30 days, percentile 88%
public exploits
0
none known

Summary

CyberPanel 2.4.3, fixed in commit eca0c3c, contains an authenticated command injection vulnerability in the remote backup transfer feature that allows authenticated attackers to execute arbitrary OS commands by controlling a remote server's API response. Attackers can inject malicious commands through a crafted directory name in the remote server's API response, which bypasses security middleware validation and is passed unsanitized to the OS command execution function.

Patch / fix

Is CVE-2026-71966 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
total
Assessed
2mo ago

Exploit prediction

3.28% chance of exploitation in the next 30 days, higher than 88% of all scored CVEs (FIRST EPSS, 2026-11-11).

Exploits and checks

  • themcsam.github.io https://themcsam.github.io/posts/cyberpanel-2.4.3-vulnerabilties/ referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • usmannasir cyberpanel

Classification

Weakness
  • CWE-78 Improper Neutralization of Special Elements used in an OS Command

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.

CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.