Skip to content
Fencer Intel
high 7.7

CVE-2026-72895 json

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC…

published 29d ago modified 27d ago also EUVD-2026-98389

cvss
7.7
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.1%
EPSS 0.1% chance of exploitation in 30 days, percentile 1%
public exploits
0
none known

Summary

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.

Patch / fix

  • Siemens SIMATIC IPC BX-21A V31.01.13
  • Siemens SIMATIC IPC RW-543A V1.1.4
  • Siemens SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G V28.01.15

Is CVE-2026-72895 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-26-295-07 updated cvss 7.7

Siemens SIMATIC IPCs

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
28d ago

Exploit prediction

0.11% chance of exploitation in the next 30 days, higher than 1% of all scored CVEs (FIRST EPSS, 2026-11-11).

CVSS scores

assigned by version score vector
CNA 3.1 7.7 CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
CNA 4.0 8.4 CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 8.4 CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Siemens SIMATIC IPC BX-21A
  • Siemens SIMATIC IPC RW-543A
  • Siemens SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G

Classification

Weakness
  • CWE-1394 Use of Default Cryptographic Key

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.