Skip to content
Fencer Intel
high 7.5

CVE-2026-78574 json

Improper Assembly Resolution in Okta Hyperdrive Integration Plugin Registry Handling

published 2mo ago modified last mo. also EUVD-2026-74175

cvss
7.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.1%
EPSS 0.1% chance of exploitation in 30 days, percentile 2%
public exploits
0
none known

Summary

The Okta Hyperdrive Integration plugin resolves a required assembly using a registry path within the current user's hive without integrity verification. The referenced path is loaded via Assembly.LoadFrom without signature validation, resulting in an unverified assembly executing within the context of the host process or elevated installer.

Patch / fix

  • Okta Okta Hyperdrive Integration Plugin 1.5.2

Is CVE-2026-78574 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
2mo ago

Exploit prediction

0.13% chance of exploitation in the next 30 days, higher than 2% of all scored CVEs (FIRST EPSS, 2026-11-11).

CVSS scores

assigned by version score vector
CNA 3.1 7.5 CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N
NVD 3.1 6.3 CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N

Affected products

  • Okta Okta Hyperdrive Integration Plugin

Classification

Weakness

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.