CVE-2026-78630 json
Improper Input Neutralization in Okta Access Gateway SNMP Configuration Processing
published 2mo ago modified last mo. also EUVD-2026-74182
- cvss
- 6.7
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 12%
- public exploits
- 0
- none known
Summary
The Okta Access Gateway does not neutralize shell metacharacters in SNMP configuration values before a privileged script uses them to construct OS commands. An authenticated local user with access to the management interface can supply crafted values, resulting in the execution of arbitrary OS commands with root privileges.
Patch / fix
- Okta Okta Access Gateway 2026.9.1
Is CVE-2026-78630 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 2mo ago
Exploit prediction
0.22% chance of exploitation in the next 30 days, higher than 12% of all scored CVEs (FIRST EPSS, 2026-11-11).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.7 | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Okta Okta Access Gateway
Classification
- Weakness
-
- CWE-78 Improper Neutralization of Special Elements used in an OS Command
References
Sources
- CVE List CVE-2026-78630
- NVD CVE-2026-78630
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.