CVE-2026-8031 json
PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication
published 6mo ago modified 16d ago also EUVD-2026-28149
- cvss
- 5.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.4%
- EPSS 0.4% chance of exploitation in 30 days, percentile 34%
- public exploits
- 0
- none known
Summary
A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit is now public and may be used. Upgrading to version 5.7.1 is sufficient to fix this issue. You should upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Patch / fix
- PicoTronica e-Clinic Healthcare System ECHS 5.7.1
Is CVE-2026-8031 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 6mo ago
Exploit prediction
0.39% chance of exploitation in the next 30 days, higher than 34% of all scored CVEs (FIRST EPSS, 2026-11-11).
Exploits and checks
- docs.google.com https://docs.google.com/document/d/1FByC9x21c5503cQg6lkxjffIwWlEAHtHi_83vk2eUdk/edit?usp=sharing referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P |
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C |
| CNA | 3.0 | 5.3 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C |
| CNA | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:OF/RC:C |
| CNA | 4.0 | 5.5 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| CNA | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:P/I:N/A:N |
Affected products
- PicoTronica e-Clinic Healthcare System ECHS
Classification
References
-
docs.google.com
/document/d/1FByC9x21c5503cQg6lkxjffIwWlEAHtHi_83vk2eUdk/edit?usp=sharing
exploit
-
vuldb.com
/vuln/361357
vdb-entry
-
vuldb.com
/vuln/361357/cti
signature, permissions-required
-
vuldb.com
/submit/800781
third-party-advisory
Sources
- CVE List CVE-2026-8031
- NVD CVE-2026-8031
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.