GHSA-8c8c-4vfj-rrpc json

Reflected Cross-Site Scripting in redis-commander

published 6y ago modified 4y ago

cvss
—
not scored
cisa kev
Not listed
not in CISA's catalog
epss
—
no score, EPSS covers CVEs only
public exploits
0
none known

Summary

Affected versions of `redis-commander` contain a cross-site scripting vulnerability in the `highlighterId` paramter of the clipboard.swf component on hosts serving Redis Commander.

Mitigating factors: Flash must be installed / enabled for this to work. The below proof of concept was verified to work using Firefox 57.0 on Windows 10 by manually installing the [Flash NPAPI Windows plugin](https://get.adobe.com/flashplayer/otherversions/)

## Proof of concept

``` http://instance/jstree/_docs/syntax/clipboard.swf?highlighterId=\%22))}%20catch(e)%20{alert(document.domain);}// ```

## Recommendation

No direct patch for this vulnerability is currently available.

At this time, the best mitigation is to use an alternative, functionally equivalent package, or to use extreme caution when using redis-commander, ensuring that redis-commmander is the only web page you have open, and avoiding clicking on any links.

Patch / fix

Is GHSA-8c8c-4vfj-rrpc in your dependencies? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Affected packages

ecosystem package affected fixed in
npm redis-commander
>=0.0.0, <0.5.0
0.5.0

Classification

Weakness
  • CWE-79 Improper Neutralization of Input During Web Page Generation

References